Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

5.3.1.2.(3)
+
Application
Application 1: 
Metal-framed glazed assemblies that are used as storm windows or doors, or that are required to have a fire-protection rating, and are installed to provide resistance to heat transfer in buildings to which Part 5 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Top of Page
Intent
Intent 1: 
To exempt certain glazed assemblies from the requirement for a thermal break stated in Sentence 5.3.1.2.(2), on the basis that:
  • the assemblies are installed as storm windows and doors, because in this application they act as a secondary protection against heat transfer, or
  • the assemblies are required to have a fire-protection rating and it is recognized that fire is a more serious hazard than inadequate thermal performance and that rated glazed assemblies with thermal breaks are unlikely to be available.