Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

5.3.1.3.(2)
OH1OS2OS1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Materials installed to provide resistance to heat transfer and air movement in, and at interfaces between, building components described in Sentence 5.1.2.1.(1) that are installed in buildings to which Part 5 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Exceptions: 
except as stated in Sentence 5.3.1.1.(2), which applies where a lack of resistance to heat transfer will not adversely affect health, safety, the intended use of the building or the operation of building services.
Top of Page
Intent
Intent 1: 
To limit the probability of wind-washing or short-circuiting, which could lead to the inadequate control of heat transfer through environmental separators under expected environmental loads, which could lead to:
  • excessive heat loss or gain, or
  • condensation.
This is to limit the probability of:
  • the inadequate control of temperatures of interior spaces,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces, and
  • the inadequate thermal comfort of persons.
This is to limit the probability of harm to persons.
Top of Page