Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

5.3.1.3.(3)
OH1OS2OS1
ObjectiveOS1 Fire Safety
Attribution
[F51,F63-OS1.4] Applies where required life safety systems are incorporated in environmental separators.
Application
Application 1: 
Spray-in-place polyurethane insulation installed to provide resistance to heat transfer in building components and assemblies as well as at interfaces between components and assemblies described in Sentence 5.1.2.1.(1) that are installed in buildings to which Part 5 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Exceptions: 
except as stated in Sentence 5.3.1.1.(2), which applies where a lack of resistance to heat transfer will not adversely affect health, safety, the intended use of the building or the operation of building services.
Top of Page
Intent
Intent 1: 
Where required life safety systems are incorporated in environmental separators, to limit the probability that the thermal performance of the installed material will fall significantly below expectations, which could lead to the inadequate control of heat transfer through environmental separators under expected environmental loads.
This is to limit the probability of compromised operation of temperature-sensitive or moisture-sensitive life safety systems, which could lead to harm to persons.
Top of Page