This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
5.8.1.1.(1) | Application | Intent |
OH1 | OS2 | + |
Objective | OS2 Structural Safety |
Attribution |
[F60-OS2.3,OS2.2]
Applies to portion of Code text: “… the bottom of
every exterior foundation wall and every floor-on-ground
shall be provided with drainage.”
|
Application | Application 1: Drainage for exterior foundation walls
and floors-on-ground. This applies to building materials,
components or assemblies and their interfaces described in Sentence 5.1.2.1.(1) that
are installed in buildings to which Part 5 applies
[see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Exceptions:
except where:
|
Top of Page | |
Intent | Intent 1: To limit the probability of excessive moisture loading on
below-ground assemblies, which could lead to moisture ingress from the ground,
which could lead to deterioration, which could lead to compromised structural
integrity of the separators or of elements supported or protected by the separators.
Intent 2: Where floors are supported on ground, to limit the probability
of reducing the soil-bearing capacity due to saturation, which could lead
to structural failure, which could lead to harm to persons. |