Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

5.8.2.1.(1)
OH1OS2
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Materials and components installed to provide resistance to moisture transfer from the ground into or through building assemblies, and through interfaces between assemblies, that separate interior space from the ground in buildings to which Part 5 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Exceptions: 
except as stated in Sentence 5.8.2.1.(2), which applies where a lack of resistance to moisture transfer from the ground will not adversely affect health, safety, the intended use of the building or the operation of building services.
Top of Page
Intent
Intent 1: 
To limit the probability of moisture ingress from the ground, which could lead to:
  • the inadequate control of relative humidity or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of environmental separators.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.