Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.3.1.3.(1) | Application | Intent |
OS2 | OP2 | OH1 | OH4 | OS3 | OS1 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Site-batched, cast-in-place concrete that is not required
to be reinforced and that is in contact with sulphate soil,
which is deleterious to normal cement, that is used in:
This applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
|
Top of Page | |
Intent | Intent 1: To limit the probability that an inadequate resistance to
sulphate salts in the soil will lead to the inadequate performance or the
premature failure of concrete under expected environmental or structural loads.
This is to limit the probability of compromised structural integrity,
which could lead to:
This is to limit the probability of harm to persons.
|
Top of Page |