Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.3.1.6.(2)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Air entrainment for site-mixed, cast-in-place concrete that is not required to be reinforced that is used in:
  • garage and carport floors, and
  • exterior steps.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of inadequate resistance to de-icing salts, water absorption or freeze-thaw stresses, which could lead to the spalling or deterioration of concrete at an unacceptable rate, which could lead to uneven surfaces, which could lead to tripping or slipping, which could lead to harm to persons.