Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.3.1.9.(1)
OS2OP2OH1OH4OS3OS1
ObjectiveOH1 Indoor Conditions
Attribution
[F20,F80-OH1.1] Applies where concrete supports or is used in the walls of chimneys or fireplaces.
[F20,F80,F61,F55-OH1.1,OH1.2] [F20,F80,F61-OH1.3] Applies where concrete supports or is used in an environmental separator.
Application
Application 1: 
Minimum and maximum temperatures of site-batched, cast-in-place concrete that is not required to be reinforced that is used in:
  • footings, foundation walls, walls, columns, grade beams and piers,
  • crawl space ground cover, and
  • basement floors, including floors of basement garages, providing lateral resistance to foundation walls.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of:
  • an excessive loss of water due to evaporation,
  • the freezing of concrete before the initial set,
  • slowed hydration of the concrete, or
  • the freezing and expansion of the excess water not used in hydration.
This is to limit the probability of:
  • a failure to develop sufficient compressive strength before building loads are applied,
  • shrinkage and cracking, or
  • the failure of internal bonds.
This is to limit the probability of:
  • where concrete supports or is used in an environmental separator
    • the compromised integrity of the environmental separator, or
    • an inadequate resistance to air and moisture transfer through the concrete, and
  • where concrete supports or is used in the walls of chimneys or fireplaces, the failure of these walls.
This is to limit the probability of:
  • pollutant ingress (from the exterior or from adjacent interior space, including soil gas, combustion products from parking garages, and particulates),
  • precipitation ingress,
  • condensation,
  • the ingress of moisture from the ground,
  • the leakage of combustion products, or
  • the compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • the generation of pollutants from biological growth or from materials that become unstable on wetting,
  • deterioration, which could lead to further compromised integrity of environmental separators, or
  • an inadequate control of indoor air and surface temperatures, drafts, relative humidity, or water accumulation.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.