Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.4.4.3.(1)
OS2OP2OH1OH4OS3
ObjectiveOH1 Indoor Conditions
Attribution
[F20-OH1.1,OH1.2,OH1.3] Applies to elements that support or are part of an environmental separator.
Application
Application 1: 
Design capacity of foundations, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where the foundation bears on gravel, sand or silt, and the water table is within a distance below the bearing surface equal to the width of the foundation.
Top of Page
Intent
Intent 1: 
For coarser soil types near the footings' bearing surface (for which free water between soil particles can reduce bearing capacity), to limit the probability of excessive soil subsidence, which could lead to the cracking of foundations or building superstructures.
Where foundations support or are part of an environmental separator, this is to limit the probability of:
  • pollutant ingress (from the exterior or from adjacent interior space, including soil gas, combustion products from parking garages, and particulates),
  • precipitation ingress,
  • condensation, or
  • moisture ingress from the ground.
This is to limit the probability of:
  • an inadequate control of relative humidity or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of elements supported by foundation walls.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.
Top of Page