Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.7.1.3.(2)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Minimum clearance in front of designated escape windows that open into window wells in bedrooms, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.7.1.2.(1), which applies to:
  • bedrooms and combination bedrooms that have direct access to the exterior through an exit door, and
  • bedrooms and combination bedrooms in sprinklered suites.
Top of Page
Intent
Intent 1: 
To limit the probability that operation of a window sash will reduce the required clearance from a window well to a designated escape window, which could lead to persons being trapped in a bedroom in an emergency, which could lead to harm to persons.