Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.7.1.5.(1)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Openable windows, in buildings of residential occupancy to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.7.1.5.(2), which applies to:
  • windows that serve dwelling units that are not located above another suite,
  • windows in which the only opening greater than 100 mm by 380 mm is a horizontal opening at the top of the window,
  • windows whose sill is located more than 450 mm above the finished floor on one side of the window, and
  • windows that are located in rooms or spaces where the finished floor described in Clause (c) is located less than 1 800 mm above the floor or ground on the other side of the window.
Top of Page
Intent
Intent 1: 
To limit the probability that inadequate fall protection, particularly for children and infants, will lead to falls from a significant height through open windows, which could lead to harm to persons.
Intent 2: 
To expand the application of Section 9.8. to include guards for windows.