Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.7.1.5.(2)
+
Application
Application 1: 
Openable windows, in buildings of residential occupancy to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]:
  • that serve dwelling units that are not located above another suite,
  • in which the only opening greater than 100 mm by 380 mm is a horizontal opening at the top of the window,
  • that have their sill located more than 450 mm above the finished floor on one side of the window, and
  • that are located in rooms or spaces where the finished floor described in Clause (c) is located less than 1 800 mm above the floor or ground on the other side of the window.
Top of Page
Intent
Intent 1: 
To exempt windows where the risk of falling or the harm that would result from a fall is limited from the application of Sentence 9.7.1.5.(1).
Top of Page