Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.8.10.2.(1)
OS2OS3OH1
ObjectiveOH1 Indoor Conditions
Attribution
Application
Application 1: 
Minimum thickness of foundation walls supporting exterior concrete steps that are cantilevered from foundation walls, of buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of failure of the foundation wall at the point of stair attachment due to dead and live loads imposed by stairs and users, which could lead to concrete cracking, which could lead to:
  • the ingress of moisture from the ground, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • an inadequate control of the temperature of interior spaces, relative humidity, water ingress and accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to compromised integrity of elements supported or protected by foundations.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.