Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.9.4.4.(1)
OS1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Protection of openings in exterior walls of buildings, where:
  • an unenclosed exterior exit stair or ramp provides the only means of egress from a suite,
  • the stair or ramp is exposed to fire from openings in the exterior walls of another fire compartment, and
  • the openings in the exterior walls of the building are within 3 m horizontally and less than 10 m below or less than 5 m above the exit stair or ramp.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability that fire will spread from a fire compartment through openings in exterior building walls to an exterior exit stair or ramp, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 2: 
To expand the application of Articles 9.10.13.5. and 9.10.13.7. to include wired glass and glass blocks in openings in exterior walls under certain conditions.