Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.9.5.5.(1)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Maximum reduction in width, by obstructions such as posts or turnstiles, of required means of egress from floor areas or parts of floor areas, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except:
  • where an alternate unobstructed means of egress is provided adjacent to and plainly visible from the restricted egress,
  • for means of egress that are within dwelling units or that serve not more than one dwelling unit, as stated in Sentence 9.9.5.1.(1), and
  • as stated in Sentence 3.8.1.3.(1), which applies to barrier-free design in buildings described in Sentence 3.8.1.1.(1) [see Sentence 9.5.2.1.(1)].
Top of Page
Intent
Intent 1: 
To limit the probability that obstructions in a required means of egress will reduce the width of the means of egress to less than the required width, which could lead to insufficient width to permit efficient egress in an emergency situation, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.