Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.9.5.8.(1) | Application | Intent |
OS3 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Location, with respect to exits,
of service rooms containing equipment subject
to possible explosion, such as boilers designed to
operate at a pressure in excess of 100 kPa, and certain types
of refrigerating and transformer equipment, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
Exceptions:
except for means of egress that are
within dwelling units or that serve not more
than one dwelling unit, as stated in Sentence 9.9.5.1.(1).
|
Top of Page | |
Intent | Intent 1: To limit the probability that an explosion in a service
room will spread to an exit, which could lead to harm to persons using the
exit. Intent 2: To limit the probability that an explosion in a service
room will spread to an exit, which could lead to the exit not being usable
in the emergency situation, which could lead to delays in the evacuation or
movement of persons to a safe place, which could lead to harm to persons.
|
Top of Page |