Warning This information has been archived because it is outdated and no longer relevant.

Archived Content

Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.9.7.4.(1)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Minimum number of egress doors from rooms and suites where the area of the rooms or suites, or the distance measured from any point within the rooms or suites to the nearest egress door, exceeds the values in Table 9.9.7.4., in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to podiums, terraces, platforms and contained open spaces, as stated in Sentence 9.9.7.1.(3).
Exceptions: 
except for dwelling units.
Top of Page
Intent
Intent 1: 
To limit the probability of an insufficient number of egress doors from a large room or suite, which could lead to inefficient egress in an emergency situation, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 2: 
To exempt situations from the application of this Sentence, where there is a lower occupant load and where occupants are likely to have an enhanced familiarity with egress facilities.
Top of Page