Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.9.7.4.(2) | Application | Intent |
OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Spacing apart of doors required in Sentence (1) [egress doors from rooms and suites where
the area of the rooms or suites, or the distance measured
from any point within the rooms or suites to the nearest
egress door, exceeds the values in Table 9.9.7.4.], in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]. Application 2: This also applies to podiums, terraces, platforms
and contained open spaces, as stated in Sentence 9.9.7.1.(3).
Exceptions:
except for dwelling units, as stated
in Sentence 9.9.7.4.(1).
|
Top of Page | |
Intent | Intent 1: To limit the probability that persons will not have access
to an alternative egress door and route in the event one door and route are
blocked or obstructed in a fire situation, which could lead to delays in the
evacuation or movement of persons to a safe place, which could lead to harm
to persons. |