Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.9.8.1.(3)
+
Application
Application 1: 
Measuring the travel distance in public corridors to at least one exit, where public corridors are not less than 9 m wide and conform to Subclauses 3.4.2.5.(1)(d)(i) to 3.4.2.5.(1)(d)(iv), in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to certain mezzanines, as stated in Sentence 9.9.8.6.(1).
Top of Page
Intent
Intent 1: 
To expand the application of Subclauses 3.4.2.5.(1)(d)(i) to 3.4.2.5.(1)(d)(iv) to Part 9 buildings.
Intent 2: 
To exempt travel distance measurements involving wide public corridors from the application of Sentences (1) and 9.9.8.2.(1), and permit a longer maximum travel distance if certain conditions are met [i.e. conformance to Subclauses 3.4.2.5.(1)(d)(i) to 3.4.2.5.(1)(d)(iv)], on the basis that, in sprinklered buildings, wide corridors that are sufficiently high will allow for a reasonable volume of smoke storage above the heads of the pedestrians.
Top of Page