Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.9.8.2.(2)
+
Application
Application 1: 
Exits from each storey in buildings of 1 and 2 storeys in building height, where:
  • the floor area and travel distance requirements conform to those required in Article 9.9.7.4., and
  • the total occupant load served by the exit facility does not exceed 60 persons.
This applies in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to certain mezzanines, as stated in Sentence 9.9.8.6.(1).
Exceptions: 
except as stated in Subsection 9.9.9., which applies to egress from dwelling units.
Top of Page
Intent
Intent 1: 
To supersede the requirements of Sentence (1), which would otherwise require at least 2 egress routes or exits, and permit a single exit, on the basis that the single exit is limited to low buildings having a relatively low occupant load and where floor areas and travel distances are limited.