Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.9.8.3.(1) | Application | Intent |
OS3 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Maximum contributing width of exits from floor areas for the purpose of determining required exit widths, where more than one exit is
required from a floor area. This
applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: This also applies to certain mezzanines,
as stated in Sentence 9.9.8.6.(1).
Exceptions:
except as stated in Sentence 3.8.1.3.(1), which applies to barrier-free design in buildings described
in Sentence 3.8.1.1.(1) [see Sentence 9.5.2.1.(1)].
|
Top of Page | |
Intent | Intent 1: To limit the probability that an excessive portion of the
required exiting capacity will be concentrated at one location, which could
lead to insufficient width in other exits to permit efficient egress in an
emergency situation if the exit becomes obstructed or inaccessible, which
could lead to delays in the evacuation or movement of persons to a safe place,
which could lead to harm to persons. |