Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.9.9.1.(2) | Application | Intent |
OS3 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Travel distance limit [number of storeys to
travel] from a floor level in a dwelling unit to
an exit or egress door, where:
This applies to dwelling
units containing more than 1 storey, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
|
Top of Page | |
Intent | Intent 1: To supersede the requirements of Sentence 9.9.9.1.(1),
which would otherwise limit the travel distance to 1 storey to reach an exit
or egress door, and permit a travel distance of more than 1 storey, if the
floor level is served by a window meeting certain conditions that limit the
probability that persons will be unable to egress from the floor level through
the window in an emergency situation, which could lead to delays in the evacuation
or movement of persons to a safe place, which could lead to harm to persons.
Intent 2: To supersede the requirements of Sentences 9.9.8.2.(1) and (2),
which would otherwise impose other travel distance or exit limitations.
|