Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.2.3.(1) | Application | Intent |
+ |
Application | Application 1: Minimum fire-resistance rating of
floors and roofs in a portion of a building containing
more than one major occupancy, where one major occupancy is located entirely above another.
This applies to buildings to which Part
9 applies [see Sentence 1.3.3.3.(1) of Division A for application of
Part 9] that contain more than one major occupancy.
Exceptions:
except as stated in Sentence 9.10.2.4.(1), which applies where:
|
Top of Page | |
Intent | Intent 1: To clarify that the requirements of Article 9.10.8.1. [pertaining
to the minimum fire-resistance ratings of floors and roofs] for each portion
of a building containing a major occupancy are to be applied to that portion
as if the entire building were of that major occupancy. |