Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.4.4.(1)
+
Application
Application 1: 
Consideration of rooftop enclosures as a storey in calculating building height, where the rooftop enclosures are:
  • provided for elevator machinery, stairways and service rooms, and
  • used for no purpose other than for service to the building.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To exclude certain rooftop enclosures from the calculation of building height, on the basis that such enclosures are normally only briefly and intermittently occupied by persons and thus do not pose an undue fire safety risk to persons.