Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.5.1.(2)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Openings for electrical and similar service outlet boxes that pierce walls or ceiling membranes forming part of an assembly required to have a fire-resistance rating, where such outlet boxes are tightly fitted.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To exempt openings for electrical and similar service outlet boxes from the requirements of Sentence 9.10.5.1.(1), which would otherwise not permit openings in rated wall or ceiling membranes, if certain conditions are met [i.e. the outlet boxes are tightly fitted].
This is to limit the probability that the openings will contribute to the spread of fire within the wall or ceiling space, which could lead to the premature failure or collapse of the wall or ceiling assembly, which could lead to harm to persons.