Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.8.1.(1)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
[F03-OS1.2] [F04-OS1.2,OS1.3] Applies to portion of Code text: “Except as otherwise provided in this Subsection, the fire-resistance ratings of floors and roofs shall conform to Table 9.10.8.1.”
Application
Application 1: 
Minimum fire-resistance ratings of floors and roofs, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Application 2: 
This also applies to:
Exceptions: 
except as stated in:
  • the provisions in Table 9.10.8.1. that apply to floors over crawl spaces, other than the crawl spaces described in Sentence 9.10.8.8.(1),
  • Sentence 9.10.8.2.(1), which applies to sprinklered buildings,
  • Sentence 9.10.8.6.(1), which applies to mezzanines that are required to be counted as storeys in Articles 9.10.4.1.and 9.10.4.2.,
  • Sentence 9.10.8.7.(1), which applies to roofs that support an occupancy,
  • Sentence 9.10.8.8.(2), which applies to the floors of exterior passageways serving buildings of Group D, E or F major occupancy that are not more than 2 storeys in building height,
  • Sentence 9.10.8.8.(3), which applies to the floors of exterior passageways serving a single dwelling unit, where no suite is located above or below the dwelling unit,
  • Sentence 9.10.8.10.(1), which applies to dwelling units that have no other dwelling unit above or below, and to dwelling units that are not above or below another major occupancy,
  • Sentence 9.10.8.11.(1), which applies to floors and roofs that conform to the appropriate requirements in Section 3.2., and
  • Sentence 9.10.21.3.(1), which applies to construction camp floor assemblies between the first storey and the second storey, other than in dwelling units.
Top of Page
Intent
Intent 1: 
To limit the probability that floors and roofs exposed to fire will fail or collapse prematurely during the time required to achieve occupant safety and for emergency responders to perform their duties, which could lead to harm to persons.
Intent 2: 
To limit the probability that floors and roofs exposed to fire will fail or collapse prematurely, which could lead to the spread of fire from a lower storey of a building to an upper storey or to the exterior of the building during the time required to achieve occupant safety and for emergency responders to perform their duties, which could lead to harm to persons.