Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.8.8.(2)
+
Application
Application 1: 
Fire-resistance rating of floors of exterior passageways serving buildings of Group D, E or F major occupancy that are not more than 2 storeys in building height.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To exempt exterior passageways serving certain buildings from the requirements of Sentence 9.10.8.8.(1), which would otherwise require the passageway floors to have a minimum fire-resistance rating, on the basis that the buildings are limited in height, travel distances from the space are short, the occupants are not expected to be sleeping, and evacuation is expected to be relatively quick.
Top of Page