Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.9.4.(3) | Application | Intent |
+ |
Application | Application 1: Floor assemblies for which no fire-resistance
rating is required by Subsection 9.10.8. and floors of mezzanines not required to be counted as storeys in Articles 9.10.4.1. and 9.10.4.2.,
in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9]. This
applies to:
|
Top of Page | |
Intent | Intent 1: To exempt certain mezzanine floors and floor assemblies
from the requirements of Sentence 9.10.9.4.(1), which would otherwise
require the floors to be fire separations, on the basis that such floors are
limited in size or number of storeys [e.g. floors above crawl spaces, floors
of exterior passageways], and are not considered to be exposed to substantial
fire hazards. |