Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.9.4.(4)
+
Application
Application 1: 
Floors above crawl spaces that are not required by Article 9.10.8.9. to be constructed as basements [i.e. crawl spaces that do not exceed 1.8�m in height and that are not used for any occupancy nor as a plenum in combustible construction nor for the passage of flue pipes ], in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To exempt floors above certain crawl spaces from the requirements of Sentence 9.10.9.4.(1), which would otherwise require the floors to be fire separations, on the basis that the height of the crawl space is limited and the crawl space is not used as an occupancy or as a plenum, and thus the crawl space is not expected to present an undue fire risk.