Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.9.4.(4) | Application | Intent |
+ |
Application | Application 1: Floors above crawl spaces that are not required by Article 9.10.8.9. to be constructed as basements [i.e.
crawl spaces that do not exceed 1.8�m in height and that are not used for
any occupancy nor as a plenum in combustible construction nor for the passage of flue pipes ], in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9]. |
Top of Page | |
Intent | Intent 1: To exempt floors above certain crawl spaces from the requirements
of Sentence 9.10.9.4.(1), which would otherwise require the floors to
be fire separations, on the basis that the height of the crawl space is limited
and the crawl space is not used as an occupancy or as a plenum, and thus the
crawl space is not expected to present an undue fire risk. |