Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.9.8.(1) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Combustible construction that
abuts on or is supported by a noncombustible fire separation, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
Exceptions:
except as stated in Sentence 9.10.9.1.(1), which applies to fire separations between rooms and spaces within dwelling units.
|
Top of Page | |
Intent | Intent 1: To limit the probability that the collapse of combustible
construction when exposed to fire will lead to the collapse of the fire separation,
which could lead to the spread of fire from one fire compartment to an adjacent
compartment, which could lead to harm to persons in the adjacent compartment.
|
Top of Page |