Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.9.11.(1) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Minimum fire-resistance rating of fire separations that separate residential
occupancies from other major occupancies.
This applies to buildings to which Part
9 applies [see Sentence 1.3.3.3.(1) of Division A for application of
Part 9].
Exceptions:
except as stated in Sentence 9.10.9.11.(2), which applies to
the separation of major occupancies classified
as residential occupancies from other major occupancies classified as mercantile or medium hazard industrial occupancies.
|
Top of Page | |
Intent | Intent 1: To limit the probability that fire will spread from one
major occupancy to an adjacent residential occupancy having a different degree
of fire risk, which could lead to harm to persons. |