Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.9.13.(2)
OS1OP1
ObjectiveOP1 Fire Protection of the Building
Attribution
Application
Application 1: 
Fire separation that separate suites of business and personal services occupancy and mercantile occupancy from each other, where the suites are served by public corridors conforming with Sentence 3.3.1.4.(4).
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are sprinklered.
Top of Page
Intent
Intent 1: 
To supersede the requirements of Sentence 9.10.9.13.(1) and not require fire separations between occupancies, on the basis that:
  • the building is sprinklered throughout, and
  • the occupancies are restricted to certain types.
This is to limit the probability that a fire involving the occupancies will spread to other parts of the building, which could lead to damage to the building.