Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.9.14.(2)
+
Application
Application 1: 
Fire separations that separate sleeping rooms in boarding and lodging houses from the remainder of the floor area as required in Sentence 9.10.9.14.(1), where:
  • sleeping accommodation is provided for not more than 8 boarders or lodgers,
  • the sleeping rooms form part of the proprietor's residence, and
  • the sleeping rooms do not contain cooking facilities.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To waive the requirements for a rated fire separation as stated in Sentences 9.10.9.13.(1) and 9.10.9.14.(1), on the basis that:
  • the number of occupants is limited,
  • all areas are under the same type of supervision as would be the case in a single dwelling unit, and
  • the absence of cooking facilities reduces the risk of fire originating in sleeping rooms.