Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.9.14.(3)
OS1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Minimum fire-resistance rating of fire separations that separate dwelling units containing 2 or more storeys including basements from the remainder of the building.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To supersede the requirements for a minimum 45 min rated fire separation as stated in Sentences 9.10.9.13.(1) and 9.10.9.14.(1) and require a higher minimum rating, on the basis that moving from one storey to another in an emergency situation could lead to increased evacuation time.
This is to limit the probability that fire will spread from one dwelling unit to other parts of the building, or from a part of the building to the dwelling unit, during the time required to achieve occupant safety, which could lead to harm to persons.