Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.9.16.(2)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Minimum fire-resistance rating of fire separations that separate storage garages from other occupancies, where such storage garages contain 5 motor vehicles or fewer.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in Sentence 9.10.9.16.(3), which applies to storage garages that serve only the dwelling unit to which they are attached or in which they are built.
Top of Page
Intent
Intent 1: 
To supersede the requirement for a minimum 1.5 h rated fire separation as stated in Sentence 9.10.9.16.(1) by permitting a lower minimum rated fire separation between storage garages, on the basis that the number of vehicles permitted in the garages is limited, thus minimizing the fire load and fire risk.
This is to limit the probability that fire will spread from a storage garage to other parts of the building, which could lead to harm to persons in the other parts of the building.