Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.9.17.(2)
+
Application
Application 1: 
Fire separations between a repair garage and ancillary spaces directly serving the repair garage, including waiting rooms, reception rooms, tool and parts storage areas and supervisory office space, where the ancillary spaces are separated from other occupancies as required in Sentence 9.10.9.17.(1).
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To clarify that ancillary spaces directly serving a repair garage may be considered as part of the repair garage, and not as another occupancy, for the purpose of determining the need for a fire separation as stated in Sentence 9.10.9.17.(1).
Intent 2: 
To exempt ancillary spaces directly serving a repair garage from the requirement for a fire separation, as stated in Sentence 9.10.9.17.(1), between such spaces and a repair garage.