Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.10.2.(1)
+
Application
Application 1: 
Fire-resistance rating requirements stated in Subsection 9.10.10. applying to floor assemblies [specifically Sentences 9.10.10.3.(1), 9.10.10.4.(1) and 9.10.10.5.(1)] that are immediately below a service room, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To exempt floor assemblies that are immediately below service rooms from the fire-resistance rating requirements in Subsection 9.10.10. [specifically Sentences 9.10.10.3.(1), 9.10.10.4.(1) and 9.10.10.5.(1)], on the basis that the condition being guarded against is a fire originating in the service room and that floor assemblies are only rated for fire originating below them.