Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.11.2.(1)
OS1OP3
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Construction of party walls on property lines between dwelling units, where the walls are constructed as fire separations having not less than a 1 h fire-resistance rating.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are of residential occupancy and in which there is no dwelling unit above another dwelling unit.
Top of Page
Intent
Intent 1: 
To supersede the requirements of Sentence 9.10.11.1.(1), which would otherwise require the party wall to be a firewall, if a certain measure is taken [i.e. the party wall is constructed as a fire separation having not less than a 1 h fire-resistance rating], on the basis that this is restricted to buildings that are limited in height in which evacuation can be expected to be relatively quick.
This [the measure] is to limit the probability that fire will spread from one dwelling unit to another, which could lead to harm to persons in the dwelling unit not originally involved in the fire.