Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.12.1.(2) | Application | Intent |
+ |
Application | Application 1: Termination of mezzanines at
vertical fire separations, where the mezzanines are
not required to be considered as storeys according
to:
This applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
|
Top of Page | |
Intent | Intent 1: To exempt certain mezzanines from the requirements of Sentence 9.10.12.1.(1), which would otherwise require mezzanines to terminate
at vertical fire separations, on the basis that the mezzanine area is limited
in size and sufficiently open to allow occupants to detect a threat to their
safety and not be excessively delayed in reaching an exit. |