Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.12.3.(2) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Minimum fire-resistance rating of
the exterior wall of each fire compartment referred
to in Sentence 9.10.12.3.(1) [where the exterior walls of the building meet
at an external angle of 135°, or less] within the 1.2 m distance
of the openings. This applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
|
Top of Page | |
Intent | Intent 1: To limit the probability that the exterior walls of fire
compartments will have insufficient fire resistance, which could lead to the
spread of fire from one fire compartment to an adjacent fire compartment through
exterior walls, which could lead to harm to persons in the adjacent fire compartment.
|
Top of Page |