Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.13.2.(1)
+
Application
Application 1: 
45-mm-thick, solid-core wood doors used as closures in fire separations, where the doors conform to CAN4-S113, “Wood Core Doors Meeting the Performance Required by CAN4-S104 for Twenty Minute Fire-Rated Closure Assemblies,” and are:
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To exempt certain door assemblies from the requirements of Sentence 9.10.13.1.(1), which would otherwise require testing to determine the fire-protection rating, on the basis that:
  • such doors are constructed in a manner that has been shown to provide the required 20 min fire performance, and
  • the fire load represented by the doors and their frames is limited, and there is no structural consequence of their eventual failure.
Top of Page