Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.13.2.(2)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Maximum clearances beneath and at the sides and top of doors described in Sentence 9.10.13.2.(1), which applies to 45-mm-thick, solid-core wood doors used as closures in fire separations, where the doors conform to CAN4-S113, “Wood Core Doors Meeting the Performance Required by CAN4-S104 for Twenty Minute Fire-Rated Closure Assemblies,” and:
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To supersede the clearances stated in NFPA 80, which is referred to in Sentence 9.10.13.1.(1), in order to limit the probability that fire will spread through gaps between a door and its frame, which could lead to harm to persons in the area on the other side of the fire compartment.