Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.13.7.(1) | Application | Intent |
+ |
Application | Application 1: Glass block used as closures in fire separations required to have a fire-resistance
rating of not more than 1 h, where the glass block has
not been tested in accordance with Sentence 9.10.3.1.(1) [i.e. not tested
in accordance with the test methods described in Part 3, Appendix A-9.10.3.1.,
or Appendix D]. This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
|
Top of Page | |
Intent | Intent 1: To supersede the requirements of Sentences 9.10.3.1.(1) and 9.13.1.1.(1), which would otherwise
require the glass block to be tested and to meet certain minimum fire-protection
ratings in accordance with certain standards, on the basis that the glass
block [which is otherwise required to be installed in conformance with Section 9.20.] provides an acceptable level of protection against
the spread of fire, in situations where the fire separation is required to
have a fire-resistance rating of not more than 1 h.
|