Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.13.16.(1) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Installation of door stops, where doors are installed
in such a way that they may damage the integrity of fire
separations if their swing is unrestricted. This
applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
|
Top of Page | |
Intent | Intent 1: To limit the probability that an unrestricted door swing
will damage a fire separation, which could lead to the spread of fire from
one compartment to another, which could lead to harm to persons in the other
fire compartment. |