Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.14.5.(6)
+
Application
Application 1: 
Fire-resistance rating, type of construction and type of cladding for heavy timber and steel columns, outside buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where the limiting distance is not less than 3 m.
Exceptions: 
except as stated in Sentence 9.10.15.1.(1), which applies to buildings that contain only dwelling units and have no dwelling unit above another dwelling unit.
Top of Page
Intent
Intent 1: 
To exempt heavy timber and steel columns from the requirements of Sentence 9.10.14.5.(1), which would otherwise impose certain minimum construction requirements relating to fire-resistance rating and type of construction, if certain conditions are met, on the basis that:
  • the limiting distance is sufficient to limit the probability of severe fire exposure of the columns in the event of a fire outside the building, and
  • the columns are outside the building and protected from exposure to a fire in the building by the exterior walls.