Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.16.1.(6) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Maximum dimension of concealed spaces described in Clause 9.10.16.1.(5)(b) [compartments formed by the separation [fire stopping]
of concealed spaces created by ceilings, roof spaces or unoccupied attic spaces,
where such spaces contain exposed construction materials having a surface flame-spread rating greater than 25, that are not
more than 300 m2 in area]. This
applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are:
|
Top of Page | |
Intent | Intent 1: To limit the probability that an extensive fire will develop
in a large concealed roof or ceiling space where surface flame spread is likely
to be relatively rapid, which could lead to the spread of fire to other parts
of the building, which could lead to harm to persons. |