Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.17.1.(2) | Application | Intent |
+ |
Application | Application 1: Doors that have a surface flame-spread
rating of not more than 200, in buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9].
Exceptions:
except as stated in Sentence 9.10.17.1.(3), which applies to
doors within dwelling units, other than garage
doors.
|
Top of Page | |
Intent | Intent 1: To exempt doors from the requirements of Sentence 9.10.17.1.(1),
which would otherwise limit surface flame-spread rating to 150, and permit
a higher maximum flame-spread rating, on the basis that the higher rating
will not contribute significantly to the spread of flame across the door surface.
|
Top of Page |