Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.10.17.8.(1)
+
Application
Application 1: 
Light diffusers and lenses having flame-spread ratings that exceed those permitted for the ceiling finish, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To exempt light diffusers and lenses from the requirements of Sentence 9.10.17.1.(1), which would otherwise limit surface flame-spread rating to 150, and permit a higher maximum flame-spread rating and require certain other conditions to be met as stated in Sentence 3.1.13.4.(1), on the basis that these building elements will not contribute significantly to the spread of flame.
Intent 2: 
To expand the application of Sentence 3.1.13.4.(1) to Part 9 buildings.