Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.17.10.(1) | Application | Intent |
OS1 | + | + |
Attribution |
(c)
|
Application | Application 1: Protection of foamed plastics from adjacent spaces
in a building, where the foamed plastics form part
of wall or ceiling assemblies in combustible construction.
This applies to buildings to which Part 9 applies
[see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions:
except:
|
Top of Page | |
Intent | Intent 1: To expand the application of Clause 3.1.5.12.(2)(e) to
Part 9 buildings. |
Top of Page |