Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
9.10.17.10.(2) | Application | Intent |
OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Thermosetting foamed plastic insulation having a flame-spread rating of not more than 200 used in factory-assembled
doors in storage garages serving single dwelling units, where:
|
Top of Page | |
Intent | Intent 1: To exempt thermosetting foamed plastic insulation used in
factory-assembled doors from the requirements of Sentence 9.10.17.10.(1),
which would otherwise require certain protective coverings over the foamed
plastic, if certain conditions are met. This is to limit
the probability that the foamed plastic insulation will be exposed to a fire,
which could lead to its ignition and contribution to the early growth and
spread of fire, which could lead to delays in the evacuation or movement of
persons to a safe place, which could lead to harm to persons.
|